Apiste Large Type ENC-A5500L
| Mount Type | Side-mount |
|---|---|
| Cooling Capacity (W) | 5000/5500 |
| Setting Temperature Range (°C) | 25 to 45 |
| Use Area Temperature (°C) | 25 to 55 |
| Use Area Humidity (%RH) | 10-85(No condensation) |
| External Dimensions (mm) | H1500×W600×D380 |
| Volume (kg) | 90 |
Apiste Non Flon & Maintenance free ENC-GR1100EX
| Mount Type | Roof-mount |
|---|---|
| Cooling Capacity (W) | 900/1000 |
| Setting Temperature Range (°C) | 25 to 45 |
| Use Area Temperature (°C) | 20 to 50 |
Apiste Non Flon & Maintenance free ENC-GR1100L
| Mount Type | Side-mount |
|---|---|
| Cooling Capacity (W) | 950/1100 |
| Setting Temperature Range (°C) | 25 to 45 |
| Use Area Temperature (°C) | 20 to 50 |
Apiste Non Flon & Maintenance free ENC-GR1500EX
| Mount Type | Roof-mount |
|---|---|
| Cooling Capacity (W) | 1350/1500 |
| Setting Temperature Range (°C) | 25 to 45 |
| Use Area Temperature (°C) | 20 to 50 |
Apiste Non Flon & Maintenance free ENC-GR1500L
| Mount Type | Side-mount |
|---|---|
| Cooling Capacity (W) | 1350/1500 |
| Setting Temperature Range (°C) | 25 to 45 |
| Use Area Temperature (°C) | 20 to 50 |
Apiste Non Flon & Maintenance free ENC-GR500EX
| Mount Type | Roof-mount |
|---|---|
| Cooling Capacity (W) | 450/500 |
| Setting Temperature Range (°C) | 25 to 45 |
| Use Area Temperature (°C) | 20 to 50 |
Apiste Non Flon & Maintenance free ENC-GR500L
| Mount Type | Side-mount |
|---|---|
| Cooling Capacity (W) | 500/600 |
| Setting Temperature Range (°C) | 25 to 45 |
| Use Area Temperature (°C) | 20 to 50 |
Apiste Non Flon ENC-GR1000EX-eco
Note: Cooling capacity 35 °C ambient temperature, the rated capacity of 35 °C when the set temperature inside the panel. Ambient humidity / ambient temperature (air enthalpy method measurement conditions JIS-C-9612) is not meant to satisfy all conditions in temperature and humidity. Rated value: 35 °C ambient temperature, ambient humidity RH 40% value at the time of use. RH 40% when the value of the maximum allowed ambient temperature, ambient humidity using an ambient temperature of use: The value MAX. The permissible ambient temperature: If you are in continuous use (less than 15 ~ 20 °C ambient), because there is a possibility of high-load operation of the compressor at low temperatures, the power supply is cut as much as possible please. Please read instructions carefully before use, please use properly.
Apiste Non Flon ENC-GR1000L-eco
Note: Cooling capacity 35 °C ambient temperature, the rated capacity of 35 °C when the set temperature inside the panel. Ambient humidity / ambient temperature (air enthalpy method measurement conditions JIS-C-9612) is not meant to satisfy all conditions in temperature and humidity. Rated value: 35 °C ambient temperature, ambient humidity RH 40% value at the time of use. RH 40% when the value of the maximum allowed ambient temperature, ambient humidity using an ambient temperature of use: The value MAX. The permissible ambient temperature: If you are in continuous use (less than 15 ~ 20 °C ambient), because there is a possibility of high-load operation of the compressor at low temperatures, the power supply is cut as much as possible please. Please read instructions carefully before use, please use properly.
Apiste Non Flon ENC-GR1500EX-eco
Note: Cooling capacity 35 °C ambient temperature, the rated capacity of 35 °C when the set temperature inside the panel. Ambient humidity / ambient temperature (air enthalpy method measurement conditions JIS-C-9612) is not meant to satisfy all conditions in temperature and humidity. Rated value: 35 °C ambient temperature, ambient humidity RH 40% value at the time of use. RH 40% when the value of the maximum allowed ambient temperature, ambient humidity using an ambient temperature of use: The value MAX. The permissible ambient temperature: If you are in continuous use (less than 15 ~ 20 °C ambient), because there is a possibility of high-load operation of the compressor at low temperatures, the power supply is cut as much as possible please. Please read instructions carefully before use, please use properly.
Apiste Non Flon ENC-GR1500L-eco
Note: Cooling capacity 35 °C ambient temperature, the rated capacity of 35 °C when the set temperature inside the panel. Ambient humidity / ambient temperature (air enthalpy method measurement conditions JIS-C-9612) is not meant to satisfy all conditions in temperature and humidity. Rated value: 35 °C ambient temperature, ambient humidity RH 40% value at the time of use. RH 40% when the value of the maximum allowed ambient temperature, ambient humidity using an ambient temperature of use: The value MAX. The permissible ambient temperature: If you are in continuous use (less than 15 ~ 20 °C ambient), because there is a possibility of high-load operation of the compressor at low temperatures, the power supply is cut as much as possible please. Please read instructions carefully before use, please use properly.
Apiste Non Flon ENC-GR500EX-eco
Note: Cooling capacity 35 °C ambient temperature, the rated capacity of 35 °C when the set temperature inside the panel. Ambient humidity / ambient temperature (air enthalpy method measurement conditions JIS-C-9612) is not meant to satisfy all conditions in temperature and humidity. Rated value: 35 °C ambient temperature, ambient humidity RH 40% value at the time of use. RH 40% when the value of the maximum allowed ambient temperature, ambient humidity using an ambient temperature of use: The value MAX. The permissible ambient temperature: If you are in continuous use (less than 15 ~ 20 °C ambient), because there is a possibility of high-load operation of the compressor at low temperatures, the power supply is cut as much as possible please. Please read instructions carefully before use, please use properly.