Apiste Large Type ENC-A5500L

Mount Type Side-mount
Cooling Capacity (W) 5000/5500
Setting Temperature Range (°C) 25 to 45
Use Area Temperature (°C) 25 to 55
Use Area Humidity (%RH) 10-85(No condensation)
External Dimensions (mm) H1500×W600×D380
Volume (kg) 90
Close

Apiste Non Flon & Maintenance free ENC-GR1100EX

Mount Type Roof-mount
Cooling Capacity (W) 900/1000
Setting Temperature Range (°C) 25 to 45
Use Area Temperature (°C) 20 to 50
Close

Apiste Non Flon & Maintenance free ENC-GR1100L

Mount Type Side-mount
Cooling Capacity (W) 950/1100
Setting Temperature Range (°C) 25 to 45
Use Area Temperature (°C) 20 to 50
Close

Apiste Non Flon & Maintenance free ENC-GR1500EX

Mount Type Roof-mount
Cooling Capacity (W) 1350/1500
Setting Temperature Range (°C) 25 to 45
Use Area Temperature (°C) 20 to 50
Browse Wishlist
Close

Apiste Non Flon & Maintenance free ENC-GR1500L

Mount Type Side-mount
Cooling Capacity (W) 1350/1500
Setting Temperature Range (°C) 25 to 45
Use Area Temperature (°C) 20 to 50
Close

Apiste Non Flon & Maintenance free ENC-GR500EX

Mount Type Roof-mount
Cooling Capacity (W) 450/500
Setting Temperature Range (°C) 25 to 45
Use Area Temperature (°C) 20 to 50
Close

Apiste Non Flon & Maintenance free ENC-GR500L

Mount Type Side-mount
Cooling Capacity (W) 500/600
Setting Temperature Range (°C) 25 to 45
Use Area Temperature (°C) 20 to 50
Close

Apiste Non Flon ENC-GR1000EX-eco

Note: Cooling capacity 35 °C ambient temperature, the rated capacity of 35 °C when the set temperature inside the panel. Ambient humidity / ambient temperature (air enthalpy method measurement conditions JIS-C-9612) is not meant to satisfy all conditions in temperature and humidity. Rated value: 35 °C ambient temperature, ambient humidity RH 40% value at the time of use. RH 40% when the value of the maximum allowed ambient temperature, ambient humidity using an ambient temperature of use: The value MAX. The permissible ambient temperature: If you are in continuous use (less than 15 ~ 20 °C ambient), because there is a possibility of high-load operation of the compressor at low temperatures, the power supply is cut as much as possible please. Please read instructions carefully before use, please use properly.
Close

Apiste Non Flon ENC-GR1000L-eco

Note: Cooling capacity 35 °C ambient temperature, the rated capacity of 35 °C when the set temperature inside the panel. Ambient humidity / ambient temperature (air enthalpy method measurement conditions JIS-C-9612) is not meant to satisfy all conditions in temperature and humidity. Rated value: 35 °C ambient temperature, ambient humidity RH 40% value at the time of use. RH 40% when the value of the maximum allowed ambient temperature, ambient humidity using an ambient temperature of use: The value MAX. The permissible ambient temperature: If you are in continuous use (less than 15 ~ 20 °C ambient), because there is a possibility of high-load operation of the compressor at low temperatures, the power supply is cut as much as possible please. Please read instructions carefully before use, please use properly.
Close

Apiste Non Flon ENC-GR1500EX-eco

Note: Cooling capacity 35 °C ambient temperature, the rated capacity of 35 °C when the set temperature inside the panel. Ambient humidity / ambient temperature (air enthalpy method measurement conditions JIS-C-9612) is not meant to satisfy all conditions in temperature and humidity. Rated value: 35 °C ambient temperature, ambient humidity RH 40% value at the time of use. RH 40% when the value of the maximum allowed ambient temperature, ambient humidity using an ambient temperature of use: The value MAX. The permissible ambient temperature: If you are in continuous use (less than 15 ~ 20 °C ambient), because there is a possibility of high-load operation of the compressor at low temperatures, the power supply is cut as much as possible please. Please read instructions carefully before use, please use properly.
Close

Apiste Non Flon ENC-GR1500L-eco

Note: Cooling capacity 35 °C ambient temperature, the rated capacity of 35 °C when the set temperature inside the panel. Ambient humidity / ambient temperature (air enthalpy method measurement conditions JIS-C-9612) is not meant to satisfy all conditions in temperature and humidity. Rated value: 35 °C ambient temperature, ambient humidity RH 40% value at the time of use. RH 40% when the value of the maximum allowed ambient temperature, ambient humidity using an ambient temperature of use: The value MAX. The permissible ambient temperature: If you are in continuous use (less than 15 ~ 20 °C ambient), because there is a possibility of high-load operation of the compressor at low temperatures, the power supply is cut as much as possible please. Please read instructions carefully before use, please use properly.
Close

Apiste Non Flon ENC-GR500EX-eco

Note: Cooling capacity 35 °C ambient temperature, the rated capacity of 35 °C when the set temperature inside the panel. Ambient humidity / ambient temperature (air enthalpy method measurement conditions JIS-C-9612) is not meant to satisfy all conditions in temperature and humidity. Rated value: 35 °C ambient temperature, ambient humidity RH 40% value at the time of use. RH 40% when the value of the maximum allowed ambient temperature, ambient humidity using an ambient temperature of use: The value MAX. The permissible ambient temperature: If you are in continuous use (less than 15 ~ 20 °C ambient), because there is a possibility of high-load operation of the compressor at low temperatures, the power supply is cut as much as possible please. Please read instructions carefully before use, please use properly.