Apiste Outdoor ENC-AR2900HD

Mount Type Side-mount
Cooling Capacity (W) 2600/2900
Setting Temperature Range (°C) 25 to 45
Use Area Temperature (°C) -5 to 55
Use Area Humidity (%RH) 10-85(No condensation)
External Dimensions (mm) H1380×W450×D295
Volume (kg) 60
Close

Apiste Outdoor ENC-AR351HD

Mount Type Side-mount
Cooling Capacity (W) 300/380
Setting Temperature Range (°C) 25 to 45
Use Area Temperature (°C) 0 to 50
Use Area Humidity (%RH) 10-85(No condensation)
External Dimensions (mm) H530×W300×D115
Volume (kg) 15
Close

Apiste Outdoor ENC-AR352HD

Mount Type Side-mount
Cooling Capacity (W) 300/380
Setting Temperature Range (°C) 25 to 45
Use Area Temperature (°C) 0 to 50
Use Area Humidity (%RH) 10-85(No condensation)
External Dimensions (mm) H530×W300×D115
Volume (kg) 15
Close

Apiste Outdoor ENC-AR510HD

Mount Type Side-mount
Cooling Capacity (W) 450/550
Setting Temperature Range (°C) 25 to 45
Use Area Temperature (°C) -5 to 50
Use Area Humidity (%RH) 10-85(No condensation)
External Dimensions (mm) H450×W350×D200
Volume (kg) 17
Close

Apiste Outdoor ENC-AR520HD

Mount Type Side-mount
Cooling Capacity (W) 450/550
Setting Temperature Range (°C) 25 to 45
Use Area Temperature (°C) -5 to 50
Use Area Humidity (%RH) 10-85(No condensation)
External Dimensions (mm) H450×W350×D200
Volume (kg) 17
Close

Apiste Standard ENC-AR422L-CU

Note: Cooling capacity 35 °C ambient temperature, the rated capacity of 35 °C when the set temperature inside the panel. Ambient humidity / ambient temperature (air enthalpy method measurement conditions JIS-C-9612) is not meant to satisfy all conditions in temperature and humidity. Rated value: 35 °C ambient temperature, ambient humidity RH 40% value at the time of use. RH 40% when the value of the maximum allowed ambient temperature, ambient humidity using an ambient temperature of use: The value MAX. The permissible ambient temperature: If you are in continuous use (less than 15 ~ 20 °C ambient), because there is a possibility of high-load operation of the compressor at low temperatures, the power supply is cut as much as possible please. Please read instructions carefully before use, please use properly.
Close

Apiste Standard ENC-AR1120EX-CU

Cooling capacity) Note: 35°C ambient temperature, the rated capacity of 35°C when the set temperature inside the panel. (Method: JIS-C-9612 air enthalpy measurement conditions) Ambient humidity / ambient temperature is not meant to satisfy all conditions in temperature and humidity. RH 40% when the value of the maximum allowed ambient temperature, ambient humidity using an ambient temperature of use: The value MAX. CE marking requirements in: noise resistance. Please read instructions carefully before use, please use properly.
Close

Apiste Standard ENC-AR1120L-CU

Cooling capacity) Note: 35°C ambient temperature, the rated capacity of 35°C when the set temperature inside the panel. (Method: JIS-C-9612 air enthalpy measurement conditions) Ambient humidity / ambient temperature is not meant to satisfy all conditions in temperature and humidity. RH 40% when the value of the maximum allowed ambient temperature, ambient humidity using an ambient temperature of use: The value MAX. CE marking requirements in: noise resistance. Please read instructions carefully before use, please use properly.
Close

Apiste Standard ENC-AR1652EX-CU

Cooling capacity) Note: 35°C ambient temperature, the rated capacity of 35°C when the set temperature inside the panel. (Method: JIS-C-9612 air enthalpy measurement conditions) Ambient humidity / ambient temperature is not meant to satisfy all conditions in temperature and humidity. RH 40% when the value of the maximum allowed ambient temperature, ambient humidity using an ambient temperature of use: The value MAX. CE marking requirements in: noise resistance. Please read instructions carefully before use, please use properly.
Close

Apiste Standard ENC-AR1652L-CU

Cooling capacity) Note: 35°C ambient temperature, the rated capacity of 35 °C when the set temperature inside the panel. (Method: JIS-C-9612 air enthalpy measurement conditions) Ambient humidity / ambient temperature is not meant to satisfy all conditions in temperature and humidity. RH 40% when the value of the maximum allowed ambient temperature, ambient humidity using an ambient temperature of use: The value MAX. CE marking requirements in: noise resistance. Please read instructions carefully before use, please use properly.
Close

Apiste Standard ENC-AR2200EX-CU

Cooling capacity) Note: 35°C ambient temperature, the rated capacity of 35°C when the set temperature inside the panel. (Method: JIS-C-9612 air enthalpy measurement conditions) Ambient humidity / ambient temperature is not meant to satisfy all conditions in temperature and humidity. RH 40% when the value of the maximum allowed ambient temperature, ambient humidity using an ambient temperature of use: The value MAX. CE marking requirements in: noise resistance. Please read instructions carefully before use, please use properly.
Close

Apiste Standard ENC-AR2200L-CU

Cooling capacity) Note: 35°C ambient temperature, the rated capacity of 35 °C when the set temperature inside the panel. (Method: JIS-C-9612 air enthalpy measurement conditions) Ambient humidity / ambient temperature is not meant to satisfy all conditions in temperature and humidity. RH 40% when the value of the maximum allowed ambient temperature, ambient humidity using an ambient temperature of use: The value MAX. CE marking requirements in: noise resistance. Please read instructions carefully before use, please use properly.