Communication Protocols:
Open standards EtherNet/IP, Modbus/TCP and others for connectivity to many peripheral devices on the market.
Standard Programming Languages:
IEC61131-3 means that programs are developed and executed with predictable behavior.
Programmable Amplifier Outputs:
The controller can operate local Sigma-5 outputs. This reduces panel cost and space requirements when just a couple of outputs are necessary.
Controller-Centric Commissioning:
The MECHATROLINK motion network provides a channel for configuring the machine from a single location with one software tool.
A Multitude of Options:
Choose from eight option cards offered for the expansion slots to accommodate most machine requirements.
Remote I/O:
Use Yaskawa’s VIPA SLIO EtherNet/P modules to meet all your remote I/O needs. Numerous third-party remote I/Os such as Phoenix, Wago, and Opto 22 can also be interfaced with the system via MECHATROLINK and Ethernet.
Web Server:
A built in web server offers standard controller diagnostic information eliminating the need for special software for maintenance personnel
Specifications
| Item | Specifications | |
| MP3300iec | ||
| Classification | Controller | |
| Name | MP3300iec | |
| Model Number | PMC-U-MP33004 (Standard Performance). CPU module, MP3300iec, 4-axis PMC-U-MP33008 (Standard Performance). CPU module, MP3300iec, 8-axis PMC-U-MP33020 (Standard Performance). CPU module, MP3300iec, 20-axis PMC-U-MP33320 (Medium Performance). CPU module, MP3300iec, 20-axis PMC-U-MP33332 (Medium Performance). CPU module, MP3300iec, 32-axis | |
| Supported Modules | LIO-01, LIO-02, LIO-04, LIO-05, LIO-06, AI-01, AO-01, DO-01 | |
| Software | MotionWorks IEC Express MotionWorks IEC Pro | |
| CPU | 400 MHz or 800 MHz | |
| Number of option module slots | 1, 3 or 8 | |
| User Variable Memory | 32 MB | |
| Power Unit | Input Voltage | 24VDC |
| Input Current | 1.0 A max (at rated input/output) for 1 slot module 1.5 A max (at rated input/output) for 3 slots module | |
| Battery | Battery for memory retention attachable at the bottom of the CPU unit | |
| Motion Network | MECHATROLINK-III: 1 channel, 2 connectors SERVOPACK and I/O for up to 20 slave nodes connectable (SERVOPACK for up to 20 axes) Baud rate: 100 Mbps (MECHATROLINK-III) | |
| Communication Function | Ethernet: 10Base-T or 100Base-TX | |
| Ethernet Protocols | Ethernet/IP and Modbus TCP/IP standard on all units, User specific protocols can be written using Y_DeviceComm firmware library | |
| Calendar | Seconds, minutes, hour, day, week, month, year, day of week, and timing (battery backup) | |
| Environmental Conditions | Ambient Operating Temperature | 0°C to 60°C (Forced cooling is required if 55°C is exceeded.) |
| Ambient Storage Temperature | -25°C to 85°C | |
| Ambient Operating Humidity | 10% to 95% RH (with no condensation) | |
| Ambient Storage Humidity | 10% to 95% RH (with no condensation) | |
| Pollution Level | Conforms to JIS B 3502 Pollution Degree 2 | |
| Corrosive Gas | There must be no combustible or corrosive gas | |
| Operating Altitude | 2,000 m above sea level or lower | |
| Mechanical Conditions | Vibration Resistance | Conforming to JIS B 3502:
|
| Shock Resistance | Size of shock: Peak acceleration of 147 m/s2 (15 G) Duration: 11ms 3 times each in the X, Y, and Z directions | |
| Electrical Operating Conditions | Noise Resistance | Conforming to EN 61000-6-2, EN 61000-6-4 and EN 55011 (Group 1, Class A) Power supply noise (FT noise): 2Kv min., for one minute Radiation noise (FT noise): 1Kv min., for one minute Ground noise (impulse noise): 1kV min., for 10 minutes Electrostatic noise (contact discharge method): 6 kV or more, 10 times |
| Installation Requirements | Ground | Ground to 100 Ω max. |
| Cooling Method | Natural cooling or forced-air cooling | |
| Connectors | M-III: MECHATROLINK, 2 connectors Ethernet: RJ 45: Ethernet RLY OUT: RLY OUT connector USB: DUSB-ARA42-T11A-FA (DDK), type A connector | |
| Indicators | RDY(green), RUN(green), ALM(red), ERR(red), BAT(red), M-ALM(red) | |
| Switches | STOP, E-INIT, INIT, CNFG, LOAD, TEST and MNT | |
| Dimensions | 64 mm X 130 mm X 108 mm (W × H × D) with 1 slot module 120 mm X 130 mm X 108 mm (W × H × D) with 3 slots module | |