Showing 25–36 of 92 results

Show sidebar
Close

Apiste Non Flon Gas & SUS ENC-GR500LE

Cooling capability: rated capability value at external temperature and humidity 35°C 40%RH, setting temperature and humidity in panel 35°C 40%RH (Setting temperature) - (differential temperature) should not be less than 20°C. Example) If the product is used at setting temperature 20°C, do not set the differential temperature to 6°C or more. If the product is continuously used at low use ambient temperature (ambient temperature 20°C or less), high load may be applied to the compressor during operation. Turn OFF the power supply as much as possible. The use ambient temperature / use ambient humidity do not fulfill all temperature and humidity conditions. Set the use power supply voltage within ±10% of rated power supply voltage. At blast: value when only the fan on evaporation side is operated at use ambient temperature 35°C, use ambient humidity 40%RH, power supply voltage 220V Rating at cooling: value at use ambient temperature 35°C, use ambient humidity 40%RH, power supply voltage 220V (out of panel) MAX at cooling: value at cooling operation when the use ambient temperature is the maximum tolerance ambient temperature at use ambient humidity 40%RH, power supply voltage 220V If the product is continuously used at low tolerance ambient temperature (ambient temperature 15 to 20°C or less), high load may be applied to the compressor during operation. To comply with UL standard, set the power supply to 3±2m. Non-drain function: at use ambient temperature / temperature in panel 35°C or less, ambient humidity / humidity in panel 85% or less
Close

Apiste Outdoor ENC-AR1010HD

unt Type Side-mount
Cooling Capacity (W) 900/1000
Setting Temperature Range (°C) 25 to 45
Use Area Temperature (°C) -5 to 50
Use Area Humidity (%RH) 10-85(No condensation)
External Dimensions (mm) H730×W300×D280
Volume (kg) 26
Close

Apiste Outdoor ENC-AR1020HD

Mount Type Side-mount
Cooling Capacity (W) 900/1000
Setting Temperature Range (°C) 25 to 45
Use Area Temperature (°C) -5 to 50
Use Area Humidity (%RH) 10-85(No condensation)
External Dimensions (mm) H730×W300×D280
Volume (kg) 26
Close

Apiste Outdoor ENC-AR1610HD

Mount Type Side-mount
Cooling Capacity (W) 1450/1600
Setting Temperature Range (°C) 25 to 45
Use Area Temperature (°C) -5 to 55
Use Area Humidity (%RH) 10-85(No condensation)
External Dimensions (mm) H1000×W400×D260
Volume (kg) 42
Close

Apiste Outdoor ENC-AR1620HD

Mount Type Side-mount
Cooling Capacity (W) 1450/1600
Setting Temperature Range (°C) 25 to 45
Use Area Temperature (°C) -5 to 55
Use Area Humidity (%RH) 10-85(No condensation)
External Dimensions (mm) H1000×W400×D260
Volume (kg) 42
Close

Apiste Outdoor ENC-AR2900HD

Mount Type Side-mount
Cooling Capacity (W) 2600/2900
Setting Temperature Range (°C) 25 to 45
Use Area Temperature (°C) -5 to 55
Use Area Humidity (%RH) 10-85(No condensation)
External Dimensions (mm) H1380×W450×D295
Volume (kg) 60
Close

Apiste Outdoor ENC-AR351HD

Mount Type Side-mount
Cooling Capacity (W) 300/380
Setting Temperature Range (°C) 25 to 45
Use Area Temperature (°C) 0 to 50
Use Area Humidity (%RH) 10-85(No condensation)
External Dimensions (mm) H530×W300×D115
Volume (kg) 15
Close

Apiste Outdoor ENC-AR352HD

Mount Type Side-mount
Cooling Capacity (W) 300/380
Setting Temperature Range (°C) 25 to 45
Use Area Temperature (°C) 0 to 50
Use Area Humidity (%RH) 10-85(No condensation)
External Dimensions (mm) H530×W300×D115
Volume (kg) 15
Close

Apiste Outdoor ENC-AR510HD

Mount Type Side-mount
Cooling Capacity (W) 450/550
Setting Temperature Range (°C) 25 to 45
Use Area Temperature (°C) -5 to 50
Use Area Humidity (%RH) 10-85(No condensation)
External Dimensions (mm) H450×W350×D200
Volume (kg) 17
Close

Apiste Outdoor ENC-AR520HD

Mount Type Side-mount
Cooling Capacity (W) 450/550
Setting Temperature Range (°C) 25 to 45
Use Area Temperature (°C) -5 to 50
Use Area Humidity (%RH) 10-85(No condensation)
External Dimensions (mm) H450×W350×D200
Volume (kg) 17
Close

Apiste Standard ENC-AR422L-CU

Note: Cooling capacity 35 °C ambient temperature, the rated capacity of 35 °C when the set temperature inside the panel. Ambient humidity / ambient temperature (air enthalpy method measurement conditions JIS-C-9612) is not meant to satisfy all conditions in temperature and humidity. Rated value: 35 °C ambient temperature, ambient humidity RH 40% value at the time of use. RH 40% when the value of the maximum allowed ambient temperature, ambient humidity using an ambient temperature of use: The value MAX. The permissible ambient temperature: If you are in continuous use (less than 15 ~ 20 °C ambient), because there is a possibility of high-load operation of the compressor at low temperatures, the power supply is cut as much as possible please. Please read instructions carefully before use, please use properly.
Browse Wishlist
Close

Apiste Standard ENC-AR1120EX-CU

Cooling capacity) Note: 35°C ambient temperature, the rated capacity of 35°C when the set temperature inside the panel. (Method: JIS-C-9612 air enthalpy measurement conditions) Ambient humidity / ambient temperature is not meant to satisfy all conditions in temperature and humidity. RH 40% when the value of the maximum allowed ambient temperature, ambient humidity using an ambient temperature of use: The value MAX. CE marking requirements in: noise resistance. Please read instructions carefully before use, please use properly.