New Compact Inverter
- High performance and multipurpose
- Fully compatible with existing products
- Easy operation and maintenance
- Energy efficient
- Network capabilities standard
- Global compatibility
Frenic-mini 0.1kW – 3.7kW 3-phase 200V Models
- FRN0.1C1S-2A : 0.1kW (1/8HP)
- FRN0.2C1S-2A : 0.2kW (1/4HP)
- FRN0.4C1S-2A : 0.4kW (1/2HP)
- FRN0.75C1S-2A : 0.75kW (1HP)
- FRN1.5C1S-2A : 1.5kW (2HP)
- FRN2.2C1S-2A : 2.2kW (3HP)
- FRN3.7C1S-2A : 3.7kW (5HP)
EMC filter built-in type
- FRN0.1C1E-2A : 0.1kW (1/8HP)
- FRN0.2C1E-2A : 0.2kW (1/4HP)
- FRN0.4C1E-2A : 0.4kW (1/2HP)
- FRN0.75C1E-2A : 0.75kW (1HP)
- FRN1.5C1E-2A : 1.5kW (2HP)
- FRN2.2C1E-2A : 2.2kW (3HP)
- FRN3.7C1E-2A : 3.7kW (5HP)
Braking resistor built-in type
- FRN1.5C1S-2A21 : 1.5kW (2HP)
- FRN2.2C1S-2A21 : 2.2kW (3HP)
- FRN3.7C1S-2A21 : 3.7kW (5HP)
IP40 enclosure type
- FRN0.1C1J-2A : 0.1kW (1/8HP)
- FRN0.2C1J-2A : 0.2kW (1/4HP)
- FRN0.4C1J-2A : 0.4kW (1/2HP)
- FRN0.75C1J-2A : 0.75kW (1HP)
- FRN1.5C1J-2A : 1.5kW (2HP)
- FRN2.2C1J-2A : 2.2kW (3HP)
- FRN3.7C1J-2A : 3.7kW (5HP)
Standard specifications
Item
|
Specifications
|
||||||||||
Type | FRN0.1C1S-2A | FRN0.2C1S-2A | FRN0.4C1S-2A | FRN0.75C1S-2A | FRN1.5C1S-2A | FRN2.2C1S-2A | FRN3.7C1S-2A | ||||
Applicable motor rating [kW] |
0.1
|
0.2
|
0.4
|
0.75
|
1.5
|
2.2
|
3.7
|
||||
Output ratings | Rated capacity [kVA] (*2) |
0.30
|
0.57
|
1.3
|
2.0
|
3.5
|
4.5
|
7.2
|
|||
Rated voltage [V] (*3) |
Three-phase 200 to 240V (With AVR)
|
||||||||||
Rated Current [A] |
0.8
(0.7) |
1.5
(1.4) |
3.5
(2.5) |
5.5
(4.2) |
9.2
(7.0) |
12.0
(10.0) |
19.1
(16.5) |
||||
Overload capability |
150% of rated current for 1min
150% of rated current for 1min or 200% of rated current for 0.5s (If the rated current is in parenthesis) |
||||||||||
Rated frequency [Hz] |
50, 60Hz
|
||||||||||
Input ratings | Phases, voltage, frequency |
Three-phase, 200 to 240V, 50/60Hz
|
|||||||||
Voltage/frequency variations |
Voltage: +10 to -15% (Voltage unbalance : 2% or less) Frequency: +5 to -5%
|
||||||||||
Momentary voltage dip capability |
When the input voltage is 165V or more,
the inverter continues operation. If it drops less than 165V, the inverter operates for 15ms. |
||||||||||
Rated current [A] (*7) | with DCR | 0.57 |
0.93
|
1.6
|
3.0
|
5.7
|
8.3
|
14.0
|
|||
without DCR |
1.1
|
1.8
|
3.1
|
5.3
|
9.5
|
13.2
|
22.2
|
||||
Required power supply capacity[kVA] |
0.2
|
0.3
|
0.6
|
1.1
|
2.0
|
2.9
|
4.9
|
||||
Braking | Torque [%] (*9) |
150
|
100
|
50
|
30
|
||||||
Braking transistor | – |
Built-in
|
|||||||||
DC injection braking |
Starting frequency: 0.0 to 60.0Hz Braking time: 0.0 to 30.0s Braking level: 0 to 100% of rated current
|
||||||||||
Applicable safety standards |
UL508C, EN 61800-5-1:2007
|
||||||||||
Enclosure (IEC60529) |
IP20 (IEC 60529:1989) / UL open type (UL50)
|
||||||||||
Cooling method |
Natural cooling
|
Fan cooling | |||||||||
Weight/Mass [kg] |
0.6
|
0.6
|
0.6
|
0.7
|
1.7
|
1.7
|
2.3
|