Specifications
| Mount Type | Roof-mount |
|---|---|
| Cooling Capacity (W) | 700/800 |
| Setting Temperature Range (°C) | 25 to 45 |
| Use Area Temperature (°C) | 20 to 50 |
| Use Area Humidity (%RH) | 10-85(No condensation) |
| External Dimensions (mm) | H338×W670×D353 |
| Volume (kg) | 30 |
| Coating Color | Color Munsell 5Y7 / 1 light beige |
| Voltage Rating (V) | Single-phase AC100 |
| Consumption Current/Rating (A) | 5.7/4.9 |
| Consumption Current/MAX (A) | 6.6/6.5 |
| Starting Current (A) | 15.6/14.7 |
| Consumption Voltage/Rating (W) | 470/475 |
| Consumption Voltage/MAX (W) | 600/640 |
| Noise Resistance | Fast Transient / LEVEL4 by burst immunity test |
| Vibration Resistance | Equivalent to JIS Z 0200 Level1 |
| Dust & Water Protection Grade | Equivalent to IP54 (internal circulation route) |
| Coolant / Filling (g) | HFC-134a 250g |
| Noise (dB) | 60/65 |
| External Output | Alarm output (a contact: No-voltage resistive load 250V 2A) |
| Display | LED RUN LED display / temperature error in the panel |
| Regulatory Compliance | EN60335-1 EN60335-2-40/EN61000-6-2 EN61000-6-4 |
| Environmental Response | RoHS |
| Note: Cooling capacity 35 °C ambient temperature, the rated capacity of 35 °C when the set temperature inside the panel. Ambient humidity / ambient temperature (air enthalpy method measurement conditions JIS-C-9612) is not meant to satisfy all conditions in temperature and humidity. Rated value: 35 °C ambient temperature, ambient humidity RH 40% value at the time of use. RH 40% when the value of the maximum allowed ambient temperature, ambient humidity using an ambient temperature of use: The value MAX. The permissible ambient temperature: If you are in continuous use (less than 15 ~ 20 °C ambient), because there is a possibility of high-load operation of the compressor at low temperatures, the power supply is cut as much as possible please. Please read instructions carefully before use, please use properly. | |
Parts list supplied
| Mounting Bolt | 4 (M6 x L12) |
|---|---|
| Flange Nut | (M6)4/(M4)2 |
| Exhaust Hose | 3m |
| L-pipe | 2 |
| INSULOK Tie | 6 |
| Washer | 2(M6) |
| Wind Direction Louver | 1 |
| User Manual | 1 |
Maintenance Parts List
| Internal Circulation Fan | Circulation fan for AR810EXE |
|---|---|
| External Fan | Air fan for G810EXE |
| Filter | ENC-F-21 |
| Vaporization Filter | Evaporation filter for G810EXE |
| Electrical Board | Substrate for G810EXE |
| Note: Please contact sales representative by availability. Because delivery time varies. The contents described in other model specifications, since specifications are subject to change without notice, Please note. |
|