Specifications
| Mount Type | Side-mount |
|---|---|
| Cooling Capacity (W) | 500/600 |
| Setting Temperature Range (°C) | 25 to 45 |
| Use Area Temperature (°C) | 20 to 50 |
| Use Area Humidity (%RH) | 10-85(No condensation) |
| External Dimensions (mm) | H450×W350×D250 |
| Volume (kg) | 28 |
| Coating Color | Color Munsell 5Y7 / 1 light beige |
| Voltage Rating (V) | Single-phase AC200 to 240 |
| Consumption Current/Rating (A) | 1.1 / 1.5 |
| Consumption Current/MAX (A) | 1.2 / 1.7 |
| Starting Current (A) | 6.1 / 5.6 |
| Consumption Voltage/Rating (W) | 240 / 300 |
| Consumption Voltage/MAX (W) | 260 / 330 |
| Vibration Resistance | 5Hz frequency 20mm total amplitude |
| Dust & Water Protection Grade | Equivalent to IP54 (internal circulation route) |
| Coolant / Filling (g) | R744 / 210 |
| Noise (dB) | 62 / 62 |
| External Output | Alarm output output / cooling operation (a contact: No-voltage resistive load 250V 2A) |
| Display | LED RUN LED display / temperature error in the panel |
| Environmental Response | RoHS |
| Note: Cooling capacity 35 °C ambient temperature, the rated capacity of 35 °C when the set temperature inside the panel. Ambient humidity / ambient temperature (air enthalpy method measurement conditions JIS-C-9612) is not meant to satisfy all conditions in temperature and humidity. Rated value: 35 °C ambient temperature, ambient humidity RH 40% value at the time of use. RH 40% when the value of the maximum allowed ambient temperature, ambient humidity using an ambient temperature of use: The value MAX. The permissible ambient temperature: If you are in continuous use (less than 15 ~ 20 °C ambient), because there is a possibility of high-load operation of the compressor at low temperatures, the power supply is cut as much as possible please. Please read instructions carefully before use, please use properly. | |
[Note]
Please use it properly Read the manual before using Delivery of the items will be passed on the car.
(Domestic location specified, except islands) will be (additional cost) Charter flights handled separately by the number, type .
Overseas at the time of delivery, we recommend packing for overseas separately.
Please check through the cooler between the FA and the power (circuit breakers) to the appropriate specification of the FA breaker cooler.
Cause of failure and be used at the rated power supply out of range.
Please use the service and maintenance on a regular basis.
Failure to maintain regular maintenance, you may be a factor in product performance degradation trouble.
When the outside temperature is low in winter, please do not let the FA cooler continuous operation. When disposing of this product, you should comply with various laws and regulations, please go to the appropriate.
Please use it properly Read the manual before using Delivery of the items will be passed on the car.
(Domestic location specified, except islands) will be (additional cost) Charter flights handled separately by the number, type .
Overseas at the time of delivery, we recommend packing for overseas separately.
Please check through the cooler between the FA and the power (circuit breakers) to the appropriate specification of the FA breaker cooler.
Cause of failure and be used at the rated power supply out of range.
Please use the service and maintenance on a regular basis.
Failure to maintain regular maintenance, you may be a factor in product performance degradation trouble.
When the outside temperature is low in winter, please do not let the FA cooler continuous operation. When disposing of this product, you should comply with various laws and regulations, please go to the appropriate.