PT Pinanggih Teknikatama PT Pinanggih Teknikatama
  • Home
  • About
    • About
    • Service Business
  • Products
  • Experience
  • Career
  • Contact
  • Article
Facebook
Twitter
Google
Email
Pinterest
subscribe
Menu
PT Pinanggih Teknikatama PT Pinanggih Teknikatama
Click to enlarge
HomeAC Panel Apiste Large Type ENC-A3500EX
Previous product
Apiste Standard ENC-AR1120L-CU
Back to products
Next product
Apiste Down Flow ENC-A1020L-DF
apiste

Apiste Large Type ENC-A3500EX

ENC-A3500EX Rich in type ceiling is the maximum cooling capacity of the domestic class, also a safety feature.

Add to Wishlist loading
Product added! Browse Wishlist
The product is already in the wishlist! Browse Wishlist
Compare
Category: AC Panel
Share
Facebook
Twitter
Google
Email
Pinterest
  • Description
  • Additional information
  • About brand
  • Order Information
Description

Specifications

Mount Type Roof-mount
Cooling Capacity (W) 3200/3500
Setting Temperature Range (°C) 25 to 45
Use Area Temperature (°C) 25 to 55
Use Area Humidity (%RH) 10~80(No condensation)
External Dimensions (mm) H500×W1000×D550
Volume (kg) 76
Coating Color Color Munsell 5Y7 / 1 light beige
Voltage Rating (V) Single-phase AC200
Consumption Current/Rating (A) 7.8/8.0
Consumption Current/MAX (A) 9.5/9.8
Starting Current (A) 33/30
Consumption Voltage/Rating (W) 1350/1600
Consumption Voltage/MAX (W) 1750/2000
Noise Resistance Fast Transient / LEVEL4 by burst immunity test
Vibration Resistance 5Hz frequency 20mm total amplitude
Dust & Water Protection Grade Equivalent to IP54 (internal circulation route)
Coolant / Filling (g) HFC-134a 740g
Noise (dB) 73/76
External Output Cooling operation output, alarm output (a non-voltage contact: Resistive load 250V 2A)
Display LED RUN LED display / temperature error in the panel
Regulatory Compliance Electrical Appliance and Material Safety Law
Note:
Cooling capacity: 35°C ambient temperature, the value of the rated capacity when the set temperature 35°C inside the panel. (Method: JIS-C-9612 air enthalpy measurement conditions)
Ambient humidity / ambient temperature is not meant to satisfy all conditions in temperature and humidity.
Rated value: 35°C ambient temperature, ambient humidity RH 40% value at the time of use.
RH 40% when the value of the maximum allowed ambient temperature, ambient humidity using an ambient temperature of use: The value MAX.
Please read instructions carefully before use, please use properly.

Parts list supplied

Mounting Bolt 6 (M8 x L25)
Exhaust Hose 3m
L-pipe 2
INSULOK Tie 6
Washer 2
Wind Direction Louver 1
Eye Bolt 4(M10)
Mounting nut 6(M8)
User Manual 1

Maintenance Parts List

Internal Circulation Fan Circulation fan for A3500EX
External Fan Air fan for A3500EX
Filter ENC-F-40 * 2
Electrical Board Substrate for A3500EX
Note:
Please contact sales representative depending on the stock status, so delivery time will vary.
The contents described in other model specifications, since specifications are subject to change without notice, Please note.
Additional information
Brand

Apiste

About brand
Apiste provides improvements for reliability of your control devices and testing/production environments through its FA air conditioners for control panels/server racks, heat exchanges, and clean & precise air conditioning systems. Product of Apiste includes Heat Prevention Units, Clean & Precision Air Conditioning Units and Infrared Thermography.
distributor apiste indonesia,apiste indonesia,repair inverter apiste,plc apiste,apiste drive,servo apiste,apiste plc
MORE PRODUCTS

Apiste 400V ENC-G2240L

Add to Wishlist loading
Product added! Browse Wishlist
The product is already in the wishlist! Browse Wishlist
Quick View
Close

Apiste 400V ENC-G2940L

Add to Wishlist loading
Product added! Browse Wishlist
The product is already in the wishlist! Browse Wishlist
Quick View
Close

Apiste Down Flow ENC-A1020L-DF

Add to Wishlist loading
Product added! Browse Wishlist
The product is already in the wishlist! Browse Wishlist
Quick View
Close

Apiste Down Flow ENC-G2200L-DF

Add to Wishlist loading
Product added! Browse Wishlist
The product is already in the wishlist! Browse Wishlist
Quick View
Close

Apiste Large Type ENC-A3500EX

Add to Wishlist loading
Product added! Browse Wishlist
The product is already in the wishlist! Browse Wishlist
Quick View
Close

Apiste Large Type ENC-A5500L

Add to Wishlist loading
Product added! Browse Wishlist
The product is already in the wishlist! Browse Wishlist
Quick View
Close
Order Information

SEND US AN EMAIL

CONTACT US

icons8-phone-64
Phone: +62-21 8080 8846
icons8-touchscreen-96
Mobile: +62-822 600 600 63
icons8-new-post-64
Email: iqbal@pinanggih.co.id,sales@pinanggih.co.id
icons8-office-phone-64
Fax: +62-21 8080 8847
icons8-map-marker-96
Address: D'MANSION Blok A20 Business Park Jl Dr.Krt Radjiman Wijodiningrat Jatinegara Indah, Pulo Gdung, Jakarta

Do you have questions about how we can help your company?
Send us an email and we’ll get in touch shortly.

Related products

Close

Rittal Thermoelectric cooler Total cooling/heating output 100 W

The powerful thermoelectric unit in a lightweight design is the ideal climate control solution for command panels and small enclosures.
Add to Wishlist loading
Product added! Browse Wishlist
The product is already in the wishlist! Browse Wishlist
Quick View
Close

Apiste Non Flon Gas & SUS ENC-GR500L-SUS

* Cooling Capacity : Rated capacity value when ambient temperature is 35°C and ambient humidity is 40%RH , power source & voltage : 200V. (Measuring specifcation :JIS B 8615-1 the inside of a air enthalpy test method) * Use area temperature / humidity : Use area temperature / humidity is not meant to satisfy all conditions in temperature and humidity. * Rating Value : 35°C ambient temperature, ambient humidity RH 40%, power source & voltage : 200V. * Maximum Value : The ambient temperature at MAX value has specifcation separately. * Use the product keeping the use power supply and voltage; within ±10% of rated power supply and rated voltage. * Consumption current and wattage are values during cooling operation. * Dust prevention / dust proof protection class : Excluding drain pipe section * Reading an instruction manual well certainly before use and please use it right.
Add to Wishlist loading
Product added! Browse Wishlist
The product is already in the wishlist! Browse Wishlist
Quick View
Close

Rittal TopTherm wall-mounted cooling units “Blue e” Total cooling output 0.50 – 0.75 kW

Energy-efficient Blue e wall-mounted cooling units in output categories from 500 W to 750 W, with integral e-Comfort controller and RiNano coating on the condenser as standard.
Add to Wishlist loading
Product added! Browse Wishlist
The product is already in the wishlist! Browse Wishlist
Quick View
Close

Rittal TopTherm wall-mounted cooling units “Blue e” Total cooling output 2.00 – 4.00 kW

Energy-efficient Blue e wall-mounted cooling units in output categories from 2,000 W to 4,000 W, with integral e-Comfort controller, RiNano coating on the condenser and electrical condensate evaporation as standard.
Add to Wishlist loading
Product added! Browse Wishlist
The product is already in the wishlist! Browse Wishlist
Quick View
Close

Apiste Non Flon Gas & SUS ENC-GR1000L-SUS

* Cooling Capacity : Rated capacity value when ambient temperature is 35°C and ambient humidity is 40%RH , power source & voltage : 200V. (Measuring specifcation :JIS B 8615-1 the inside of a air enthalpy test method) * Use area temperature / humidity : Use area temperature / humidity is not meant to satisfy all conditions in temperature and humidity. * Rating Value : 35°C ambient temperature, ambient humidity RH 40%, power source & voltage : 200V. * Maximum Value : The ambient temperature at MAX value has specifcation separately. * Use the product keeping the use power supply and voltage; within ±10% of rated power supply and rated voltage. * Consumption current and wattage are values during cooling operation. * Dust prevention / dust proof protection class : Excluding drain pipe section * Reading an instruction manual well certainly before use and please use it right.
Add to Wishlist loading
Product added! Browse Wishlist
The product is already in the wishlist! Browse Wishlist
Quick View
Close

Rittal Modular climate control concept – section door TS 8 for installing cooling modules

Sheet steel section doors for the installation of climate control module types SK 3307.7XX to 3310.7XX.
Add to Wishlist loading
Product added! Browse Wishlist
The product is already in the wishlist! Browse Wishlist
Quick View
Close

Rittal TopTherm wall-mounted cooling units “Blue e” Total cooling output 1.00 – 1.50 kW

Energy-efficient Blue e wall-mounted cooling units in output categories from 1,000 W to 1,500 W, with integral e-Comfort controller, RiNano coating on the condenser and electrical condensate evaporation as standard.
Add to Wishlist loading
Product added! Browse Wishlist
The product is already in the wishlist! Browse Wishlist
Quick View
Close

Apiste Non Flon Gas & SUS ENC-GR1100LE

Cooling capability: rated capability value at external temperature and humidity 35°C 40%RH, setting temperature and humidity in panel 35°C 40%RH (Setting temperature) - (differential temperature) should not be less than 20°C. Example) If the product is used at setting temperature 20°C, do not set the differential temperature to 6°C or more. If the product is continuously used at low use ambient temperature (ambient temperature 20°C or less), high load may be applied to the compressor during operation. Turn OFF the power supply as much as possible. The use ambient temperature / use ambient humidity do not fulfill all temperature and humidity conditions. Set the use power supply voltage within ±10% of rated power supply voltage. At blast: value when only the fan on evaporation side is operated at use ambient temperature 35°C, use ambient humidity 40%RH, power supply voltage 220V Rating at cooling: value at use ambient temperature 35°C, use ambient humidity 40%RH, power supply voltage 220V (out of panel) MAX at cooling: value at cooling operation when the use ambient temperature is the maximum tolerance ambient temperature at use ambient humidity 40%RH, power supply voltage 220V If the product is continuously used at low tolerance ambient temperature (ambient temperature 15 to 20°C or less), high load may be applied to the compressor during operation. To comply with UL standard, set the power supply to 3±2m. Non-drain function: at use ambient temperature / temperature in panel 35°C or less, ambient humidity / humidity in panel 85% or less
Add to Wishlist loading
Product added! Browse Wishlist
The product is already in the wishlist! Browse Wishlist
Quick View
Yokogawa
Yaskawa
Yamatake
WEG
Toshiba
Terasaki
Teco
Sumitomo Technologies
Siemens
Schneider
Rittal
Pro Face
Panasonic
Omron
MKCells
Mitsubishi Electric
Idec
ICP DAS
Fuji ELectric
Franklin
© 2021 PT Pinanggih Teknikatama. All rights reserved.Maknative Konsultan Pajak Rumah Kayu jasa konsultan pajak Sewa Truk Mobil Golf
close
Start typing to see products you are looking for.
  • Home
  • About
    • About
    • Service Business
  • Products
  • Experience
  • Career
  • Contact
  • Article
Scroll To Top