LD (Low Duty) Spec for ligh load
Wide Model Variation
Basic Type
Suitable for the equipment that uses a peripheral device to suppress noise or harmonics
EMC filter built-in type
By adopting built-in filter, this type is compliant with European EMC Directives category C3 (2nd Env) ‘EN61800-3-2004’.
Frenic Mega 75kW to 630kW 400V 3-phase
- FRN5.5G1E-4A (7.5kW 400V 3 phase)
- FRN7.5G1E-4A (11kW 400V 3 phase)
- FRN11G1E-4A (15kW 400V 3 phase)
- FRN15G1E-4A (18.5kW 400V 3 phase)
- FRN18.5G1E-4A (22kW 400V 3 phase)
- FRN22G1E-4A (30kW 400V 3 phase)
- FRN30G1E-4A (37kW 400V 3 phase)
- FRN37G1E-4A (45kW 400V 3 phase)
- FRN45G1E-4A (55kW 400V 3 phase)
- FRN55G1E-4A (75kW 400V 3 phase)
5.5 kW to 55 kW High Duty specification for heavy load
Item
|
Specifications
|
|||||||||||||||
Type (FRN□□□G1E-4□) |
5.5
|
7.5
|
11
|
15
|
18.5
|
22
|
30
|
37
|
45
|
55
|
||||||
Nominal applied motor [kW] (*1) |
7.5
|
11
|
15
|
18.5
|
22
|
30
|
37
|
45
|
55
|
75
|
||||||
Output ratings | Rated capacity [kVA] (*2) |
12
|
17
|
22
|
28
|
33
|
45
|
57
|
69
|
85
|
114
|
|||||
Rated voltage [V] (*3) |
Three-phase 380 to 480V (with AVR)
|
|||||||||||||||
Rated Current [A] |
16.5
|
23
|
30.5
|
37
|
45
|
60
|
75
|
91
|
112
|
150
|
||||||
Overload capability |
120% for 1min
|
|||||||||||||||
Rated frequency [Hz] |
50, 60Hz
|
|||||||||||||||
Input ratings | Main circuit power Phases, voltage, frequency |
Three-phase 380 to 480V, 50/60Hz
|
||||||||||||||
Auxiliary control power input Phases, voltage, frequency |
Single-phase 380 to 480V, 50/60Hz
|
|||||||||||||||
Auxiliary power input for fan Phases, voltage, frequency (*5) |
–
|
|||||||||||||||
Voltage, frequency variations |
Voltage:+10 to -15% (Voltage unbalance:2% or less (*6)) Frequency:+5 to -5%
|
|||||||||||||||
Rated current [A] (*7) | with DCR |
14.4
|
21.1
|
28.8
|
35.5
|
42.2
|
57.0
|
68.5
|
83.2
|
102
|
138
|
|||||
without DCR |
23.2
|
33.0
|
43.8
|
52.3
|
60.6
|
77.9
|
94.3
|
114
|
140
|
–
|
||||||
Required power supply capacity [kVA] (*8) | with DCR |
10
|
15
|
20
|
25
|
30
|
40
|
48
|
58
|
71
|
96
|
|||||
Braking | Torque [%] (*9) |
70%
|
15%
|
7 to 12%
|
||||||||||||
Braking transistor |
Built-in
|
–
|
||||||||||||||
Min. ohmic value [Ω] Torque [%] |
64
130% |
48
120% |
32
130% |
24
140% |
16
150% |
16
130% |
–
|
|||||||||
Built-in braking resistance |
80Ω
|
–
|
||||||||||||||
Braking time[s]
|
3.7s
|
3.4s |
–
|
|||||||||||||
%ED
|
2.2
|
1.4
|
–
|
|||||||||||||
DC injection braking |
Starting frequency:0.0 to 60.0Hz, Braking time: 0.0 to 30.0s, Braking level:0 to 80%
|
|||||||||||||||
EMC filter |
EMC standard compliance: Category C3 is only emission and 2nd Env. is immunity. (EN61800-3:2004)
|
|||||||||||||||
DC reactor (DCR) (*10) |
Optional
|
Standard accessory
|
||||||||||||||
Applicable safety standards |
UL508C, C22.2No.14 (pending), EN61800-5-1:2003
|
|||||||||||||||
Enclosure (IEC60529) |
IP20 (IEC60529) closed type, UL open type (UL 50)
|
IP00 open type, UL open type
|
||||||||||||||
Cooling method |
Fan cooling
|
|||||||||||||||
Weight/Mass [kg] |
7.1
|
7.6
|
7.6
|
10.7
|
10.7
|
11.2
|
26
|
26
|
32
|
36
|